Ozone Grout NS

Non shrink ready to use cementitious grout.

Category:

 

Download “Ozone Grout NS Flyer”

Ozone_Grout_NS.pdf – Downloaded 173 times – 416.63 KB
Description Ozone Grout NS is a ready to use, non-shrink cementitious grout. It can be used as fluid or plastic consistencies for grouting of equipment and machinery, bearing pads, rails and anchoring.
Primary Applications Machine foundations.
Grouting bearing pads and plinths.
Grouting under machinery base plates, stanchion bases and crane rails.
Underpinning.
Completely filling the void between a base plate and a substrate.
It can also be used for anchoring a wide range of fixings. These include masts, anchor bolts and fence posts.
Pre-Cast panels & structural supports.
General concrete repairs.
Features / Benefits Gaseous expansion system compensates for shrinkage and settlement in the plastic state.
No metallic iron content to cause staining.
Prepackaged material overcomes potential on-site batching variations.
Develops high early strength without the use of chlorides.
High ultimate strength and low permeability ensure the durability of the hardened grout.
Non-shrink providing full structural support.
Extended working time in warm weather.
Standards compliance Complies with ASTM C 1107 as Type C and CCRD-C621-83-10.2
Properties The following results were developed under laboratory conditions at 25°C.

Compressive strength BS 1881 part 116 1983 25 N/mm2 @ 1 day
2 45 N/mm2 @ 7 days
2 65 N/mm2 @ 28 days
Flexural strength BS 4551 1980 10.0 N/mm @ 28 days
Time for expansion start 15 – 20 minutes
Finish 1.5 – 2.0 hours
Fresh wet density Approximately1850kg/m
depending on actual
consistency used
Modulus of elasticity ASTM C 469-02 : 24000 mpa
Expansion characteristics
An expansion of up to 2%
Overcomes plastic settlement in the unset
material.

 

Packaging 15Kg,25 Kg bag
Storage Store in dry and cool place below 35 C. Protect from direct sunlight.
Shelf life 12 months if stored properly in original unopened packaging.
Instruction for use Watch Points: The temperature of both the grout and elements coming into contact with the grout should be in the range of 10°C –25°C. Do not use water in an amount or at a temperature that will produce a flow of less than 20 seconds (CRD-C79-77) or cause mixed grout to bleed or segregate. If outside that range, special information on high and low temperature grouting techniques are available from your local Ozone representative or technical services department. When the grout will be in contact with steel which is or will be stressed to over 550 mpa, do not use Ozone Grout NS, consult 0zone technical Services Department for steel which will be stressed to over 550 mpa or for post-tensioned cables and strands.
Surface preparation: All surfaces must be clean and sound. Remove all surface laitance by acid etching or grinding, also dust and debris. All surfaces should be thoroughly wetted 6–24 hours before starting and be in a moist condition during placing. Any free surface water must be removed before application.Mixing: For optimum results a high shear paddle or vane grout mixer should be used. Colloidal impeller mixers are not suitable for use with this product. Air entrainment should be avoided. For large or continuous placement ensure that adequate mixing capacity and sufficient labor is available. A holding tank fitted with agitation may be used. Add the correct amount of water for the required consistency to the mixer and then add the complete pack(s) slowly while mixing. Mix for a further 3 –4 minutes until smooth and cohesive. Allow to stand for 1 minute before use. Re-Mix and use immediately.
Yield: Quantity of water required to be added 25 kg bags to achieve the desired consistency and yield are below:

Consistency Water Yields
Trowel-able 3.40 – 3.6 liters 12.00 liters
Flow-able 4.00 – 4.5 liters 13.25 liters

Application: Ensure sufficient material is available to complete the work and obtain a continuous fill. Pour from one side only to avoid air entrapment, keeping a head on the grout to promote flow. Do not vibrate but rods, straps and chains can be used to aid complete filling. A high gravity feed may also be used.
Grouting large volumes: Ozone Grout NS may be used up to 75mm thick sections. Above this the addition of clean, graded 10mm aggregates at up to one to one by weight is recommended. In this instance normal concrete mixers and pumps may be used.
Pumping: Ozone Grout NS may be placed using piston, ram or diaphragm type grout pumps fitted with ball valves. In all cases, ensure maximum restraint is maintained, otherwise compressive strength will be reduced.
Curing: Proper curing procedures are important to ensure the durability and quality of the grout. Cure the grout with a high solids curing compound, such as Ozone CureCrete compound must be ordered separately.

Cleaning & Disposal Clean tools and equipment with water before the material hardens. Do not dispose off into water or soil but according to local regulations.
Precautions & Limitations Do not add any admixture or fluidities.
Proper curing is required.
Employ cold weather or hot weather grouting practices as the temperatures dictates.
Do not use as a topping.
Do not use material at temperatures that may cause premature freezing. Rate of strength gain is significantly affected at temperature extremes.
Health & safety Ozone Grout NS is alkaline and should not come into contact with skin and eyes. Avoid inhalation of dust during mixing. Gloves, goggles and dust mask should be worn. If contact with skin occurs, wash with water. Splashes to eyes should be washed immediately with plenty of clean water and medical advice sought.

WARRANTY: Ozone products are guaranteed against defective materials and manufacture and are sold subject to their standard terms and conditions of sale. Ozone makes no warranties, implied or otherwise, as to the merchantability or fitness for ordinary or particular purposes of its products and excludes the same. If any Ozone product fails to conform to this warranty, Ozone will replace the product at no cost to the Buyer. Replacement of any product shall be the sole and exclusive remedy available and the buyer shall have no claim for incidental or consequential damages. Any warranty claim must be made period from the date of the claimed breach. Ozone does not authorize anyone on its behalf to make any written or oral statements which in any way alter Ozone’s installation information or instructions in its product literature or on its packaging labels. The user of the Ozone products must test the products for suitability for the intended application and purpose before proceeding with the full application of the products.